Hemaray 51
Features:
- 30 parameters including 4 research parameters, 3 scattergrams and 3 histograms
- Tri-angular laser scatter + Flow cytometry for 5-partWBC counting
- Independent BASO counting channel
- 4 TFT Colored LCD with Touch Screen
- Throughput: 60 samples per hour
- Sample Type: Whole Blood, Peripheral Blood, Pre-diluted Blood
- Built-in Thermal printer
- Data Storage: 100,000 sample results
Hemaray 83
Features:
- 28 Parameters, 2 Histograms, 2 Scattergrams
- Laser Scatter Technology
- 3-D Topographic Maps for WBC
- Cyanide Free reagent
- Constant Linear Sheath Flow
- Integral Titanium Incubation System
- 2 test modes & 2 sample modes
- Throughput: 60 samples/hour
DOWNLOAD BROCHURE
Hemaray 86
Features:
- 28 Parameters, 2 Histograms, 2 Scattergrams
- Laser Scatter Technology
- 3-D Topographic Maps for WBC
- Cyanide Free reagent
- Constant Linear Sheath Flow
- Integral Titanium Incubation System
- 2 test modes & 2 sample modes
- Autoloader
- Throughput: 60 samples/hour
DOWNLOAD BROCHURE
Rayto Chemray 120
Features:
- Automatic, Random Access
- Throughput: 120 tests per hour
- Reagent cooling and pre-heating, liquid level detection
- Analytical modes: End-point, two-point, kinetic
- Sample Position: 9 positions
- Reagent Position: 26 positions
- Refrigerated reagent tray
- Reaction Position: 90 cuvettes, 10 cuvettes per strip
- Reaction Volume: 180-500μl
- Probe: collision protection, Liquid Level Detection and inventory checking
Rayto Chemray 330
Features:
- Automatic, Random Access
- Analytical Modes: End-point, two-point, kinetic
- Throughput: Constant speed 200 tests per hour
- Automatic 8-step washing system, low carry-over
- 24 hours non-stop reagent cooling compartment
- Sample Position: 40 positions
- Reagent Position: 40 reagent positions in refrigerated compartment
- Reaction Position: 81 cuvettes, 9 cuvette per strip
- Probe: Collision protection, Liquid level detection and inventory checking
Rayto Chemray-240
Features:
- Automatic, Random Access
- Throughput: up to 160 tests per hour
- Analytical Modes: End-point, Two-point, Kinetic
- Automatic 8-steps washing system
- Sample Position: 40 positions
- Reagent Position: 40 positions in refrigerated compartment
- Reaction Position: 81 cuvettes, 9 cuvettes per strip
- Reaction Volume: 180-500μl
- Independent mixing probe
Rayto RT-9200
Features:
• Easy keypad Operation with LCD display
• Wavelength from 330-800nm; 5 standard filters, 3 optional
• Supports flowcell and cuvette mode
• Analytical modes include kinetic, two-point, bichromatic end-point with or without reagent blank or sample blank, linear or non-linear calibration curve
• Memory of 60 programs and 2200 test results
• Excellent QC function
• Internal thermal-sensitive printer