Showing all 9 results

DiaSys Respons 920

Features:
  • System Type: Automated bench top random access clinical chemistry analyzer
  • Throughput: 200 test per hour with a cycle time of 18 seconds for mono and two component tests
  • Sample tray: 30 sample positions including STAT positions, 9 positions for blank, controls and calibrators
  • Reagent on-board capacity: 30 different methods in bar coded mono or twin containers, refrigerated
  • Reaction Unit: temperature controlled heated rotor with 45 reusable quartz glass cuvettes (37 ± 0.2°C)
  • Photometry: 8 wavelengths (340, 405, 450,505, 546, 578, 660 and 700nm (mono and bichromatic))
  DOWNLOAD BROCHURE

DiaSys Respons 940

Features:
  • System Type: Automated random access clinical chemistry analyzer
  • Throughput: 400 test per tests, independently for mono and two component reagents
  • Sample disk: 80 positions for samples, blanks, standards, calibrators, controls, STAT samples
  • Reagent on-board capacity: 72 reagent positions (R1+R2), refrigerated
  • Reaction Unit: 72 permanent hard glass cuvettes (37 ± 0.2°C)
  • Photometry: 12 wavelengths (340, 376, 415, 450, 480, 505, 546, 570, 600, 660, 700 and 705 nm)

Goldsite GBA-1000

Features:
  • Methods: End-point, fixed time, kinetic, turbidimetry
  • Throughput: up to 100 test per hour
  • Reagent Position: 45 positions
  • Display: 10.4 inch color touch screen
  • Reaction Disk: 8 x 10 cuvettes
  • Printer: Built-in thermal printer

Rayto Chemray 120

Features:
  • Automatic, Random Access
  • Throughput: 120 tests per hour
  • Reagent cooling and pre-heating, liquid level detection
  • Analytical modes: End-point, two-point, kinetic
  • Sample Position: 9 positions
  • Reagent Position: 26 positions
  • Refrigerated reagent tray
  • Reaction Position: 90 cuvettes, 10 cuvettes per strip
  • Reaction Volume: 180-500μl
  • Probe: collision protection, Liquid Level Detection and inventory checking

Rayto Chemray 330

Features:
  • Automatic, Random Access
  • Analytical Modes: End-point, two-point, kinetic
  • Throughput: Constant speed 200 tests per hour
  • Automatic 8-step washing system, low carry-over
  • 24 hours non-stop reagent cooling compartment
  • Sample Position: 40 positions
  • Reagent Position: 40 reagent positions in refrigerated compartment
  • Reaction Position: 81 cuvettes, 9 cuvette per strip
  • Probe: Collision protection, Liquid level detection and inventory checking

Rayto Chemray-240

Features:
  • Automatic, Random Access
  • Throughput: up to 160 tests per hour
  • Analytical Modes: End-point, Two-point, Kinetic
  • Automatic 8-steps washing system
  • Sample Position: 40 positions
  • Reagent Position: 40 positions in refrigerated compartment
  • Reaction Position: 81 cuvettes, 9 cuvettes per strip
  • Reaction Volume: 180-500μl
  • Independent mixing probe

Rayto RT-9200

Features: • Easy keypad Operation with LCD display • Wavelength from 330-800nm; 5 standard filters, 3 optional • Supports flowcell and cuvette mode • Analytical modes include kinetic, two-point, bichromatic end-point with or without reagent blank or sample blank, linear or non-linear calibration curve • Memory of 60 programs and 2200 test results • Excellent QC function • Internal thermal-sensitive printer  

RIELE Photometer 4040

Features:
  • Type: Single-beam filter photometer
  • Light Source: LED with  long lifetime
  • Wavelength: 330-730nm; 6 standard filters + 3 optional filter of choice
  • Cuvette System: Normal standard cuvette (macro or semi-micro, disposable or special optical glass)
  • Memory: capacity for up to 231 programmable methods
  • Data Logging: up to 1000 test results can be saved
  • Quality Control: up to 50 methods, Levey-Jennings plot
  • Integrated Printer: Thermal printer, 24 characters per line

RIELE Photometer 5010

Features:
  • Type: Semi-automatic, single-beam filter photometer
  • Light Source: LED with long lifetime
  • Wavelength: 340 to 730nm; 6 standard filters + 3 optional filter of choice
  • Cuvette System: Micro flow cell; 32μl, 10 mm light path interchangeable with normal standard cuvettes (macro or semi-micro, disposable or special optical glass)
  • Aspiration System: Built-in peristaltic pump driven by stepper motor
  • Memory: Capacity for up to 231 programmable methods
  • Data Logging: up to 1000 test results can be saved
  • Quality Control: up to 50 methods, Levey-Jennings plot
  • Integrated Printer: Thermal printer, 24 characters per line