tPSA FIA Test
Features:
- Quantitative, non-subjective results
- Increased sensitivity and broader detection range compared to rapid tests
- Range
- Precision
- Accuracy
- Linearity
- Individually sealed foil pouches containing:
- One test device
- One desiccant
- Detection buffer tubes
- SD card
- Instructions for Use
- Clock or timer
- RaFIA Immunofluorescence Analyzer
- RaFIA Immunofluorescence Incubator
TSH FIA Test
Features:
- Quantitative, non-subjective results
- Increased sensitivity and broader detection range compared to rapid tests
- Working range: 0.4–100.0 μIU/mL
- Intra-lot Precision: Intra-lot precision was determined by testing of TSH reference materials using 10 test devices from the same lot. CV ≤ 15%.
- Inter-lot Precision: Inter-lot precision was determined by testing of TSH reference materials using 30 test devices from 3 consecutive lots randomly (10 test devices from each lot). CV ≤20%.
- TSH control materials with two different concentrations were tested by every lot of test device, and the deviations were within ±15%.
- A serial concentration of TSH reference materials at 0.4-100.0 μIU/mL was tested, and the correlation coefficient (R) is ≥0.9900.
- Individually sealed foil pouches containing: a. One test device b. One desiccant
- Detection buffer tubes
- SD card
- Instructions for Use
- Clock or timer
- RaFIA Immunofluorescence Analyzer
- RaFIA Immunofluorescence Incubator
CATALOG # | PRODUCT | QUANTITY | SPECIMEN |
F1030 |
TSH FIA Test |
25/kit |
Serum, Plasma |
β-hCG FIA Test
Features:
- Quantitative, non-subjective results
- Increased sensitivity and broader detection range compared to rapid tests
- Working range: 5.0-200000.0 mIU/mL
- Intra-lot Precision: Intra-lot precision was determined by testing of β-hCG reference materials using 10 test devices from the same lot. CV ≤ 15%.
- Inter-lot Precision: Inter-lot precision was determined by testing of β-hCG reference materials using 30 test devices from 3 consecutive lots randomly (10 test devices from each lot). CV ≤ 20%.
- β-hCG control materials with two different concentrations were tested by every lot of test device, and the deviations were within ±15%.
- A serial concentration of β-hCG reference materials at 5.0-200000.0 mIU/mL was tested, and the correlation coefficient (R) is ≥0.9900.
- REAGENTS AND MATERIALS PROVIDED:
- Individually sealed foil pouches containing: a. One test device b. One desiccant
- Detection buffer tubes
- SD card
- Instructions for Use
- Clock or timer
- RaFIA Immunofluorescence Analyzer
- RaFIA Immunofluorescence Incubator
- REAGENTS AND MATERIALS PROVIDED:
- Individually sealed foil pouches containing: a. One test device b. One desiccant
- Detection buffer tubes
- SD card
- Instructions for Use
- Clock or timer
- RaFIA Immunofluorescence Analyzer
- RaFIA Immunofluorescence Incubator
CATALOG # | PRODUCT | QUANTITY | SPECIMEN |
F1000 |
β-hCG FIA Test |
25/kit |
Serum, Plasma |