HbA1c FIA Test
Features:
- Quantitative, non-subjective results
- Increased sensitivity and broader detection range compared to rapid tests
- Working range: 4%–15%
- Intra-lot Precision Intra-lot precision was determined by testing of HbA1c reference materials using 10 test devices from the same lot. CV ≤ 15%
- Inter-lot Precision Inter-lot precision was determined by testing of HbA1c reference materials using 30 test devices from 3 consecutive lots randomly (10 test devices from each lot). CV ≤ 20%.
- HbA1c control materials with three different concentrations were tested by every lot of test device, and the deviations were within ±15%.
- A serial concentration of HbA1c reference materials at 4%–15% was tested, and the correlation coefficient (R) is ≥0.9900.
- REAGENTS AND MATERIALS PROVIDED:
- Individually sealed foil pouches containing: a. One test device b. One desiccant
- Detection buffer tubes
- SD card
- Instructions for Use
- Clock or timer
- RaFIA Immunofluorescence Analyzer
- RaFIA Immunofluorescence Incubator
CATALOG # | PRODUCT | QUANTITY | SPECIMEN |
F6100 |
HbA1c FIA Test |
25/kit |
Serum, Plasma |
Immunofluorescence Analyzer
ACCURACY:
- Less than 3% intra-run CV
- Eliminates subjective interpretation by operator
- Results comparable to lab-based CLIA analyzer
- System uses an SD card to ensure the proper test is being run
- Able to run whole blood, serum, plasma and urine specimens
- Touch screen interface for easy operation
- Lightweight (2.9 kg) and portable
- Results presented on screen or via the built-in printer
- Storage capacity of 10,000 test results
-
SPECIFICATIONS Human Machine Interface: 4.3-inch LCD touch screen Dimensions: 280(L)×256(W)×102(H)mm Weight: 2.9 kg Power Adapter: 100-240 VAC, 50-60Hz Data output: On screen/Printer OPERATION ENVIRONMENT Temperature: 10~30℃ Humidity: ≤70% Atmosphere pressure: 85.0~106.0 Kpa Operation Altitude: <2000m Location: Dry, clean, flat, horizontal surface, away from direct sunlight, mechanical vibration, and strong electromagnetic interference. STORAGE ENVIRONMENTAL Temperature: 0~50℃ Humidity: ≤93% Storage Elevation: 0~2000m OPTICAL DESCRIPTION Excitation Light Source: LED 365nm Detector: Silicon photodiode
Immunofluorescence Incubator
ACCURACY:
• Incubation system control temperature variation ≤± 0.1℃
EASE-OF-USE:
• Simple temperature adjustment
• Easy incubation time-setting for each channel
• Portable and lightweight (1.4 kg)
• Incubation completion reminder chime for user convenience
• 6-channel incubator to increase throughput
SPECIFICATIONS | |
Dimensions: | 255(L)×135(W)×40(H)mm |
Weight: | 1.4 kg |
Power Adapter: | 100-240 VAC, 50 Hz, 60W |
Temperature Setting: | 20~40℃ |
Time Setting: | 3~30 min |
OPERATION CONDITIONS | |
Temperature: | 10~30℃ |
Humidity: | ≤95% |
Atmosphere Pressure: | 85.0~106.0KPa |
Operation Altitude: | <2000m |
STORAGE CONDITIONS | |
Temperature: | 0~55℃ |
Humidity: | ≤80% |
LH FIA Test
Features:
- Quantitative, non-subjective results
- Increased sensitivity and broader detection range compared to rapid tests
- Working range: 1.0-200.0 mIU/mL
- Intra-lot Precision Intra-lot precision was determined by testing of LH reference materials using 10 test devices from the same lot. CV ≤ 15%.
- Inter-lot Precision Inter-lot precision was determined by testing of LH reference materials using 30 test devices from 3 consecutive lots randomly (10 test devices from each lot). CV ≤ 20%.
- LH control materials with three different concentrations were tested by every lot of test device, and the deviations were within ±15%.
- A serial concentration of LH reference materials at 1.0-200.0 mIU/mL was tested, and the correlation coefficient (R) is ≥0.9900.
- REAGENTS AND MATERIALS PROVIDED:
- Individually sealed foil pouches containing: a. One test device b. One desiccant
- Detection buffer tubes
- SD card
- Instructions for Use
- Clock or timer
- RaFIA Immunofluorescence Analyzer
- RaFIA Immunofluorescence Incubator
CATALOG # | PRODUCT | QUANTITY | SPECIMEN |
F1090 |
LH FIA Test |
25/kit |
Serum, Plasma |
MAU FIA Test
Features:
- Quantitative, non-subjective results
- Increased sensitivity and broader detection range compared to rapid tests
- Working range: 2.0-300.0 mg/L
- Intra-lot Precision: Intra-lot precision was determined by testing of MAU reference materials using 10 test devices from the same lot. CV ≤ 15%.
- Inter-lot Precision: Inter-lot precision was determined by testing of MAU reference materials using 30 test devices from 3 consecutive lots randomly (10 test devices from each lot). CV ≤ 20%.
- MAU control materials with three different concentrations were tested by every lot of test device, and the deviations were within ±15%.
- A serial concentration of MAU reference materials at 2.0-300.0 mg/L was tested, and the correlation coefficient (R) is ≥0.9900.
- REAGENTS AND MATERIALS PROVIDED:
- Individually sealed foil pouches containing: a. One test device b. One desiccant
- Detection buffer tubes
- SD card
- Instructions for Use
- Clock or timer
- RaFIA Immunofluorescence Analyzer
- RaFIA Immunofluorescence Incubator
CATALOG # | PRODUCT | QUANTITY | SPECIMEN |
F2020 |
MAU FIA Test |
25/kit |
Urine |
MYO FIA Test
Features:
- Quantitative, non-subjective results
- Increased sensitivity and broader detection range compared to rapid tests
- Working range: 2.5-400.0 ng/mL
- Intra-lot Precision Intra-lot precision was determined by testing of MYO reference materials using 10 test devices from the same lot. CV ≤ 15%
- Inter-lot Precision Inter-lot precision was determined by testing of MYO reference materials using 30 test devices from 3 consecutive lots randomly (10 test devices from each lot). CV ≤ 15%.
- MYO control materials with three different concentrations were tested by every lot of test device, and the deviations were within ±15%.
- A serial concentration of MYO reference materials at 20.0-400.0 ng/mL was tested, and the correlation coefficient (R) is ≥0.9900.
- REAGENTS AND MATERIALS PROVIDED:
- Individually sealed foil pouches containing: a. One test device b. One desiccant
- Detection buffer tubes
- SD card
- Instructions for Use
- Clock or timer
- RaFIA Immunofluorescence Analyzer
- RaFIA Immunofluorescence Incubator
CATALOG # | PRODUCT | QUANTITY | SPECIMEN |
F3030 |
MYO FIA Test |
25/kit |
Serum, Plasma |
NT-proBNP FIA Test
Features:
- Quantitative, non-subjective results
- Increased sensitivity and broader detection range compared to rapid tests
- Working range: 15–35000 pg/mL
- Intra-lot Precision: Intra-lot precision was determined by testing of NT-proBNP reference materials using 10 test devices from the same lot. CV ≤ 15%.
- Inter-lot Precision: Inter-lot precision was determined by testing of NT-proBNP reference materials using 30 test devices from 3 consecutive lots randomly (10 test devices from each lot). CV ≤ 15%.
- NT-proBNP control materials with two different concentrations were tested by every lot of test device, and the deviations were within ±15%.
- A serial concentration of NT-proBNP reference materials at 15–35000 pg/mL was tested, and the correlation coefficient (R) is ≥0.9900.
- Individually sealed foil pouches containing: a. One test device b. One desiccant
- Detection buffer tubes
- SD card
- Instructions for Use
- Clock or timer
- RaFIA Immunofluorescence Analyzer
- RaFIA Immunofluorescence Incubator
PCT FIA Test
Features:
PRODUCT FEATURES
- Quantitative, non-subjective results
- Increased sensitivity and broader detection range compared to rapid tests
- Working range: 0.1–100.0 ng/mL
- Intra-lot Precision Intra-lot precision was determined by testing of PCT reference materials using 10 test devices from the same lot. CV ≤ 15%.
- Inter-lot Precision Inter-lot precision was determined by testing of PCT reference materials using 30 test devices from 3 consecutive lots randomly (10 test devices from each lot). CV ≤ 20%.
- PCT control materials with three different concentrations were tested by every lot of test device, and the deviations were within ±15%.
- A serial concentration of PCT reference materials at 0.1–100.0 ng/mL was tested, and the correlation coefficient (R) is ≥0.9900.
- REAGENTS AND MATERIALS PROVIDED:
- Individually sealed foil pouches containing: a. One test device b. One desiccant
- Detection buffer tubes
- SD card
- Instructions for Use
- Clock or timer
- RaFIA Immunofluorescence Analyzer
- RaFIA Immunofluorescence Incubator
CATALOG # | PRODUCT | QUANTITY | SPECIMEN |
F0400 |
PCT FIA Test |
25/kit |
Serum, Plasma, Whole blood |
PRL FIA Test
Features:
- Quantitative, non-subjective results
- Increased sensitivity and broader detection range compared to rapid tests
- Working range: 5.0-4000.0 μIU/mL
- Intra-lot Precision Intra-lot precision was determined by testing of PRL reference materials using 10 test devices from the same lot. CV ≤ 15%
- Inter-lot Precision Inter-lot precision was determined by testing of PRL reference materials using 30 test devices from 3 consecutive lots randomly (10 test devices from each lot). CV ≤ 20%.
- PRL control materials with three different concentrations were tested by every lot of test device, and the deviations were within ±15%.
- A serial concentration of PRL reference materials at 5.0-4000.0 μIU/mL was tested, and the correlation coefficient (R) is ≥0.9900.
- REAGENTS AND MATERIALS PROVIDED:
- Individually sealed foil pouches containing: a. One test device b. One desiccant
- Detection buffer tubes
- SD card
- Instructions for Use
- Clock or timer
- RaFIA Immunofluorescence Analyzer
- RaFIA Immunofluorescence Incubator
CATALOG # | PRODUCT | QUANTITY | SPECIMEN |
F1080 |
PRL FIA Test |
25/kit |
Serum, Plasma |
Progesterone FIA Test
Features:
Reagents and Materials provided:
- Quantitative, non-subjective results
- Increased sensitivity and broader detection range compared to rapid tests
- Range
- Precision
- Accuracy
- Linearity
- Specificity
Crossed Factors | Concentration | Test Result |
Estradiol | 500 ng/mL | < 0.3 ng/mL |
Testosterone | 500 ng/mL | < 0.3 ng/mL |
Cortisol | 500 ng/mL | < 0.3 ng/mL |
Aldosterone | 500 ng/mL | < 0.3 ng/mL |
Estriol | 100 ng/mL | < 0.3 ng/mL |
17-β Estradiol | 100 ng/mL | < 0.3 ng/mL |
Oestrone | 100 ng/mL | < 0.3 ng/mL |
17-α hydroxyl progesterone | 100 ng/mL | < 0.3 ng/mL |
- Individually sealed foil pouches containing:
- One test device
- One desiccant
- Detection buffer tubes
- SD card
- Instructions for Use
- Clock or timer
- RaFIA Immunofluorescence Analyzer
- RaFIA Immunofluorescence Incubator
SNIBE Maglumi 600
Features:
- Principle: Chemiluminescence Immunoassay (CLIA) System
- Throughput: up to 180 tests per hour
- Sample Position: up to 16 sample tubes
- Continuous sample loading, STAT available
- Reagent Position: 4 reagents on board
- Refrigerated reagent area
- Reagent RFID Tag with built-in master curve and information
- Calibration stability: maximum of 4 weeks
- Probe: Liquid Level Detection, Clot Detection
SNIBE Maglumi 800
Features:
- Principle: Chemiluminescence Immunoassay (CLIA) System
- Throughput: up to 180 tests per hour
- Sample Position: up to 40 sample tubes
- Continuous sample loading, STAT available
- Reagent Position: 9 reagents on board
- Refrigerated reagent area
- Reagent RFID Tag with built-in master curve and information
- Calibration stability: maximum of 4 weeks
- Probe: Liquid Level Detection, Clot Detection