Erba EC-90 Electrolyte Analyzer
Ferritin FIA Test
Features:
- Quantitative, non-subjective results
- Increased sensitivity and broader detection range compared to rapid tests
- Working range: 1.0-1000.0 ng/mL
- Intra-lot Precision Intra-lot precision was determined by testing of Ferritin reference materials using 10 test devices from the same lot. CV ≤ 15%.
- Inter-lot Precision Inter-lot precision was determined by testing of Ferritin reference materials using 30 test devices from 3 consecutive lots randomly (10 test devices from each lot). CV ≤ 20%.
- Ferritin control materials with three different concentrations were tested by every lot of test device, and the deviations were within ±15%.
- A serial concentration of Ferritin reference materials at 2.0-1000.0 ng/mL was tested, and the correlation coefficient (R) is ≥0.9900.
- REAGENTS AND MATERIALS PROVIDED:
- Individually sealed foil pouches containing: a. One test device b. One desiccant
- Detection buffer tubes
- SD card
- Instructions for Use
- Clock or timer
- RaFIA Immunofluorescence Analyzer
- RaFIA Immunofluorescence Incubator
CATALOG # | PRODUCT | QUANTITY | SPECIMEN |
F5010 |
Ferritin FIA Test |
25/kit |
Serum, Plasma |
FOB Rapid Test CE
Features:
- Designed to specifically detect low levels of fecal occult blood, hHB ≥ 50 ng/mL
- Higher accuracy, sensitivity and specificity than the Guaiac Test
- No dietary restrictions
- Clear, easy-to-interpret result
- Individually sealed foil pouches containing:
- One cassette test device.
- One desiccant
- Stool collection devices, each containing 2 mL of extraction buffer (REF SB-R2010)
- Patient ID stickers
- One package insert (instruction for use)
-
CATALOG # PRODUCT QUANTOTY SPECIMEN R2010C
FOB Rapid Test
25/kit
Fecal
FOB-Hi Rapid Test CE
- Features:
- Designed to specifically detect low levels of fecal occult blood, hHB ≥ 25 ng/mL
- Higher accuracy, sensitivity and specificity than the Guaiac Test
- No dietary restrictions
- Clear, easy-to-interpret result
- Individually sealed foil pouches containing:
- One cassette test device
- One desiccant
- Stool collection devices, each containing 2 mL of extraction buffer (REF SB-R2011)
- Patient ID stickers
- One package insert (instruction for use)
CATALOG # PRODUCT QUANTOTY SPECIMEN R2011C
FOB-Hi Rapid Test
25/kit
Fecal
fPSA FIA Test
Features:
- Quantitative, non-subjective results
- Increased sensitivity and broader detection range compared to rapid tests
- Working range: 0.1-30.0 ng/mL
- Intra-lot precision was determined by testing of fPSA reference materials using 10 test devices from the same lot. CV ≤ 15%.
- Inter-lot precision was determined by testing of fPSA reference materials using 30 test devices from three consecutive lots randomly (10 test devices from each lot). CV ≤ 20%.
- fPSA control materials with three different concentrations were tested by every lot of test device, and the deviations were within ±15%.
- A serial concentration of fPSA reference materials at 0.1-30.0 ng/mL was tested, and the correlation coefficient (R) is ≥ 0.9900.
- Reagents and Materials provided:
- Individually sealed foil pouches containing:
- One test device
- One desiccant
- Detection buffer tubes
- SD card
- Instructions for Use
- Clock or timer
- RaFIA Immunofluorescence Analyzer
- RaFIA Immunofluorescence Incubator
- Individually sealed foil pouches containing:
FSH FIA Test
Features:
-
- Quantitative, non-subjective results
- Increased sensitivity and broader detection range compared to rapid tests
- Working range: 0.30-200.00 mIU/mL
- Intra-lot Precision Intra-lot precision was determined by testing of FSH reference materials using 10 test devices from the same lot. CV ≤ 15%.
- Inter-lot Precision Inter-lot precision was determined by testing of FSH reference materials using 30 test devices from 3 consecutive lots randomly (10 test devices from each lot). CV ≤ 20%.
- FSH control materials with three different concentrations were tested by every lot of test device, and the deviations were within ±15%
- A serial concentration of FSH reference materials at 1.00-200.00 mIU/mL was tested, and the correlation coefficient (R) is ≥0.9900.
- REAGENTS AND MATERIALS PROVIDED:
- Individually sealed foil pouches containing: a. One test device b. One desiccant
- Detection buffer tubes
- SD card
- Instructions for Use
- Clock or timer
- RaFIA Immunofluorescence Analyzer
- RaFIA Immunofluorescence Incubator
CATALOG # | PRODUCT | QUANTITY | SPECIMEN |
F1100 |
FSH FIA Test |
25/kit |
Serum, Plasma |
GE100 Blood Glucose Monitoring System
GE100 Blood Glucose Test Strips
GE200 Blood Glucose Monitoring System
Features:
- Auto coding
- Measurement Technology: GDH / Electrochemical Sensor
- Minimum Sample Volume: 0.75μl
- Blood Sample Source: Capillary, venous, arterial and neonatal whole blood
- HCT Range: Glucose concentration ≤1 mmol/L, HCT Range: 20-70%
- Measuring Range: 0.6 – 33.3 mmol/L (10 – 600 mg/dL)
- Test Time: 5 seconds
- Power Supply: 2 CR2032 Batteries